Skip to main content

Non-surgical procedure repairs severed nerves in minutes



Professor George Bittner and his colleagues at the University of Texas at Austin Center for Neuroscience have developed a simple and inexpensive procedure to quickly repair severed peripheral nerves.
The team took advantage of a mechanism similar to that which permits many invertebrates to regenerate and repair nerve damage. The new procedure, based on timely application of common chemicals to the severed nerve ends, could help patients to recover nearly full function in days or weeks.
Peripheral nerves connect the central nervous system to the muscles and sensory organs. Nerves contain a bundle of cylindrical sheaths called axons, within which reside individual nerve cells. The axons are surrounded by Schwann cells which coat the axons with myelin.
Trauma to peripheral nerves is relatively common. A nerve that has been damaged by pressure or stretching generally has a severed nerve fiber inside an intact axon. A severed nerve occurs when both the nerve fiber and the axon are cut in two. Either injury can prevent muscles from working and result in loss of feeling from the area of the body served by that nerve, often for years thereafter.

Why is nerve repair in mammals such a slow process?

When a nerve fiber breaks within its axon, the broken end of the nerve fiber which is no longer connected to the central nervous system dies, leaving an empty axonal tube from the point of injury. The nerve fiber will slowly grow within the empty tube, at a rate of about an inch per month. Thus, even minor nerve injuries commonly take months or years to heal. Even then the regrown nerves rarely meet up perfectly with the original muscles and sensory organs, so that a significant amount of function is permanently lost.
In what is known as Grade V neurotmesis, the axon is severed along with the nerve fiber. The growth of the regenerating nerve fiber is not constrained, and can form a twisted ball of nerve fiber at the cut in the axon. Such nerve scars are called neuroma, and can be extremely painful. Recovery from Grade V nerve injury is never rapid, usually taking months or years for even partial recovery.
In current medical practice, a cut nerve is repaired by using microsutures to reconnect the cut ends of the axon in an extraordinarily delicate operation (imagine sewing together two limp strands of angel hair pasta).
The object is to provide a continuous axon to guide the regrowth of the nerve fiber. Again, the regrowth process takes months or years to be completed, and typically the function of the original nerve will remain impaired.

A new approach

Professor Bittner's team had discovered earlier that when a plasma membrane is damaged, a calcium-mediated healing mechanism starts to draw small vesicles toward the site of the injury. Vesicles are small sacks made of lipid membranes which provide the material needed to repair an injured plasma membrane. However, when the vesicles are attracted to the site of a severed axon, both ends of the axon are sealed off by this repair mechanism, preventing regrowth of the nerve.
To avoid this problem, the first step of the Texas group's nerve repair procedure is to bathe the area of the severed nerve with a calcium-free saline solution. By removing calcium from the injured axons, premature healing of the axon ends by this vesicle-based repair mechanism is prevented and even reversed. The damaged axons remain open, and can more easily be reattached. The calcium-free solution also contains antioxidants (e.g., methylene blue) to prevent degenerative changes in the axon and nerve.
In standard methods, the two ends of the severed axon would be reattached surgically. In contrast, Bittner's procedure does not require such difficult microsurgery. Instead, the severed ends of the axon are pulled to within a micron of each other, whereupon a small amount of a solution containing polyethylene glycol (PEG) is injected. The PEG removes water from the axonal membranes, allowing the plasma membranes to merge together, thereby healing the axon.
At the same time, the nerve fibers are brought into close enough proximity that they receive chemical messengers from each other making them believe they are still whole, thereby preventing the death of the disconnected nerve fiber. The severed nerve fibers can then grow together in a short period of time and with relatively good fidelity to the original connectivity of the nerve fibers.
The final step of the procedure is to inject the area with a calcium-rich saline solution, which restarts the vesicle-based repair mechanism, thereby repairing any residual damage to the axonal membrane. At this point, the nerve is structurally repaired, and use of the affected area begins to return within a few hours.
Indeed, tests of Bittner's procedure on rats have indicated an amazing level of success. The sciatic nerve of the rats was cleanly severed, resulting in paralysis of the affected limb.
Within minutes of awaking from Bittner's procedure, many of the rats were immediately able to move the limb containing the severed nerve. The normal function of the limb was partially restored within a few days, and 80-90% of the pre-injury function was restored within two to four weeks. Control rats subjected to sciatic nerve cutting followed by a sham procedure permanently lost nearly all (95-98%) function in the affected limb.
The chemicals used in Bittner's procedure are common and well understood in interaction with the human body. PEG is on the FDA's GRAS (generally recognized as safe) list, and methylene blue is an aromatic dye used for staining histological samples, as well as in fabric stains and paints. Because of this, there is no clear obstacle to beginning human clinical trials of the procedure. Indeed, teams at Harvard Medical School and Vanderbilt Medical School and Hospitals are currently conducting studies aimed at gaining approval for such trials. While the procedure developed by Bittner's group will not apply to the central nervous system or spinal cord injuries, the procedure offers hope to people whose futures include accidents involving damaged nerves.

Comments

Popular posts from this blog

Google and Stanford early adopters of Honda Fit EV

Honda's first all-electric vehicle is hitting the streets a little early. The  Honda Fit EV  debuted at the Los Angeles Auto Show in November 2011, and it's expected to be     available for lease this summer. However,  Honda announced  that Google and Stanford University got a special early delivery of the tiny EV this week.The Honda Fit EV is equipped with a 20kWh lithium ion battery, and has an EPA estimated driving range of 76 miles. Google added the EV to its  car -sharing service for employees, dubbed the G-Fleet, in    Mountain View, Calif. The search giant maintains several electric and plug-in vehicles that it uses for research and to cart Googlers around town and between buildings on campus. Stanford University also is an early adopter of the Fit EV, but will be using it primarily for research. The university's automotive research department will study the difference in psychological and physical reactions of using battery...

Hand-manipulated objects and transparent displays - the computer desktop of tomorrow

A see-through screen, digital 3D objects manipulated by hand, perspective adjustments according to the user's viewing angle - these are the core features of a prototype computer desktop user interface created by Microsoft's Applied Sciences Group. The prototype uses a "unique" Samsung transparent OLED display through which the user can see their own hands to manipulate 3D objects which appear to be behind the screen. A demo video appears to show a working prototype of a computer markedly different from those we use today. Yes it includes a familiar keyboard and trackpad - but these are placed behind the OLED display. The user simply lifts their hands from these input devices to manipulate on-screen (or more accurately  behind -screen) objects, such as selecting a file or window. The video shows the interface in action with a series of program windows stacked behind one another, with the user selecting the desired program by hand, using the depth of the w...

Bioengineers develop smart, self-healing hydrogel

Velcro is pretty handy stuff, but imagine if there was a soft, stretchy material with the same qualities. Well, now there is. Scientists from the University of California, San Diego have created a self-healing hydrogel that binds together in seconds, essentially copying the Velcro process at a molecular level. The new material could potentially find use in medical sutures, targeted drug delivery, industrial sealants and self-healing plastics. The secret to the jello-like polymer hydrogel is its "dangling side chain" molecules, that reach out toward one another like long, spindly fingers. When developing the gel, a team led by bioengineer Shyni Varghese ran computer simulations, in order to determine the optimal length for these molecules. The resulting substance is capable of healing cuts made to itself - or of bonding with another piece of hydrogel - almost instantly. The behavior of the material can be controlled by adjusting the pH of its environment. In lab t...